Dec 25, 2025 Leave a message

Operating Procedures, Maintenance, and Precautions for the Alkali Cleaning Area of Aluminum Extrusion Molds

Operating Procedures, Maintenance, and Precautions for the Alkali Cleaning Area of Aluminum Extrusion Molds

 

Maintenance

1. Clean the alkali sediment in the alkali washing tank in a timely manner every day.

2. Check the operation of the steam boiler daily, inspect the boiler pipes for aging and any potential hazards, and fill out the shift handover record.

3. Clean the inside of the steam boiler every half month.

 

Precautions

Workers handling molds in and out of the caustic wash tank must wear safety goggles, rubber gloves, and other protective equipment:

1. Add caustic soda and water appropriately based on the specifications of the extrusion mold and urgency; the water level generally should slightly cover the lifting ring.

2. After washing the extrusion mold, remove it from the caustic wash tank (when taking out the mold, rubber gloves, safety goggles, and other protective equipment must be worn) and promptly rinse the work surface with clean water. Pay special attention to thoroughly rinsing threaded holes, distribution holes, and lifting ring holes before opening the mold.

3. Use professional tools to open the mold, apply suitable hammer force evenly to prevent damage to the work surface. Importantly, personnel must stand on the curved side of the mold when opening the mold.

4. After rinsing, send the mold screws, molds, and mold pads to the mold repair area. Put away used tools and return them to their designated places for convenient use next time. (Screws that cannot be sent to the mold repair area must be properly stored.)

5. The caustic solution in the sedimentation tank should be discharged periodically in a comprehensive manner, and caustic residues should be cleaned regularly. 

Send Inquiry

whatsapp

Phone

E-mail

Inquiry